{"id":133,"date":"2012-07-19T08:43:56","date_gmt":"2012-07-19T08:43:56","guid":{"rendered":"https:\/\/www.akustik-forschung.de\/test\/?p=133"},"modified":"2021-11-11T10:25:00","modified_gmt":"2021-11-11T09:25:00","slug":"bauakustische-auslegung-schallschutz","status":"publish","type":"post","link":"https:\/\/www.akustikforschung.de\/en\/leistungen\/bau-und-raumakustik\/bauakustik\/bauakustische-auslegung-schallschutz\/","title":{"rendered":"Design with respect to building acoustics &#8211; Noise protection"},"content":{"rendered":"<p><a href=\"https:\/\/www.akustikforschung.de\/wp-content\/uploads\/2012\/07\/iStock_000005457175XSmall.jpg\" rel=\"gallery\"><img loading=\"lazy\" decoding=\"async\" class=\"alignright wp-image-1910 size-medium\" src=\"https:\/\/www.akustikforschung.de\/wp-content\/uploads\/2012\/07\/iStock_000005457175XSmall-e1614956859841-300x199.jpg\" alt=\"Noise control - Design of buildings with respect to building acoustics, composition of certificates for noise control\" width=\"300\" height=\"199\" srcset=\"https:\/\/www.akustikforschung.de\/wp-content\/uploads\/2012\/07\/iStock_000005457175XSmall-e1614956859841-300x199.jpg 300w, https:\/\/www.akustikforschung.de\/wp-content\/uploads\/2012\/07\/iStock_000005457175XSmall-e1614956859841.jpg 448w\" sizes=\"auto, (max-width: 300px) 100vw, 300px\" \/><\/a><\/p>\n<p>Concerning building acoustics, the Gesellschaft f\u00fcr Akustikforschung Dresden mbH provides advice for planning and optimization of both present and emerging rooms and buildings.<\/p>\n<p>Particularly, this includes the acoustic design and the measurement of the airborne sound insulation and impact sound insulation of separating building elements as well as the structure-borne sound isolation\/ vibration isolation of machines and installations.<\/p>\n<p>The preparation of certificates for noise control is a basic element of our services.<\/p>\n<p><!--contentpartdivider--><\/p>\n<h4>Calculation, design and optimization &#8211; Certificates for noise control<\/h4>\n<ul>\n<li>calculation of airborne sound propagation and structure-borne sound propagation in buildings:\n<ul>\n<li>rated airborne sound reduction index according to VDI 4100, DIN\u00a04109, DIN EN 12354 and further standards<\/li>\n<li>rated impact sound pressure level according to VDI 4100, DIN\u00a04109, DIN EN 12354 and further standards<\/li>\n<li>characteristic noise emission values of technical sound sources &#8211; industrial control elements for gas and liquid flows according to VDI\u00a03738<\/li>\n<li>noise control against noise of elevators according to VDI\u00a02566<\/li>\n<\/ul>\n<\/li>\n<li>Composition of certificates for noise control<\/li>\n<\/ul>\n<h4>Measurement of parameters of building elements with respect to building acoustics<\/h4>\n<ul>\n<li>measurement of airborne sound insulation and impact sound insulation in buildings:\n<ul>\n<li>rated airborne sound reduction index according to DIN\u00a0EN\u00a0ISO\u00a016283-1, DIN EN ISO 717-1, DIN EN ISO 10848<\/li>\n<li>rated impact sound pressure level according to DIN\u00a0EN\u00a0ISO\u00a016283-2, DIN\u00a0EN ISO 717-2, DIN EN ISO 10848<\/li>\n<li>characteristic noise emission values of technical sound sources &#8211; industrial control elements for gas and liquid flows according to VDI\u00a03738<\/li>\n<\/ul>\n<\/li>\n<li>measurement of parameters with respect to building acoustics of building elements in test setups for windows, doors, walls and ceilings\n<ul>\n<li>rated airborne sound reduction index according to DIN\u00a0EN\u00a0ISO\u00a010140-2; rating according to DIN EN ISO 717-1<\/li>\n<li>rated impact sound pressure level according to DIN EN ISO 10140-3; rating according to DIN EN ISO 717-2<\/li>\n<li>impact sound reduction of floor constructions according to DIN\u00a0EN\u00a0ISO\u00a0140\u20113; rating according to DIN EN ISO 717-2<\/li>\n<\/ul>\n<\/li>\n<\/ul>\n<p><!--contentpartdivider--><\/p>\n<div id=\"attachment_9279\" style=\"width: 310px\" class=\"wp-caption alignright\"><a href=\"https:\/\/www.akustikforschung.de\/wp-content\/uploads\/2015\/07\/bauakustik_raumakustik_abu_dhabi_ed_ws.jpg\" rel=\"gallery\"><img loading=\"lazy\" decoding=\"async\" aria-describedby=\"caption-attachment-9279\" class=\"wp-image-9279 size-medium\" src=\"https:\/\/www.akustikforschung.de\/wp-content\/uploads\/2015\/07\/bauakustik_raumakustik_abu_dhabi_ed_ws-e1614956883584-300x225.jpg\" alt=\"Reference project: preparation of certificate for noise control for exhibition center in Abu Dhabi (building acoustics - airborne sound insulation, impact sound insulation, vibration isolation in case of ground motion; room acoustics - reverberation time, sound propagation)\" width=\"300\" height=\"225\" srcset=\"https:\/\/www.akustikforschung.de\/wp-content\/uploads\/2015\/07\/bauakustik_raumakustik_abu_dhabi_ed_ws-e1614956883584-300x225.jpg 300w, https:\/\/www.akustikforschung.de\/wp-content\/uploads\/2015\/07\/bauakustik_raumakustik_abu_dhabi_ed_ws-e1614956883584-640x480.jpg 640w, https:\/\/www.akustikforschung.de\/wp-content\/uploads\/2015\/07\/bauakustik_raumakustik_abu_dhabi_ed_ws-e1614956883584-768x576.jpg 768w, https:\/\/www.akustikforschung.de\/wp-content\/uploads\/2015\/07\/bauakustik_raumakustik_abu_dhabi_ed_ws-e1614956883584.jpg 1024w\" sizes=\"auto, (max-width: 300px) 100vw, 300px\" \/><\/a><p id=\"caption-attachment-9279\" class=\"wp-caption-text\">Reference project: Design of exhibition center in Abu Dhabi with respect to building acoustics and room acoustics<\/p><\/div>\n<div id=\"attachment_4597\" style=\"width: 310px\" class=\"wp-caption alignright\"><a href=\"https:\/\/www.akustikforschung.de\/wp-content\/uploads\/2012\/07\/spezialkonstruktion_01_ed_ws.png\" rel=\"gallery\"><img loading=\"lazy\" decoding=\"async\" aria-describedby=\"caption-attachment-4597\" class=\"wp-image-4597 size-medium\" src=\"https:\/\/www.akustikforschung.de\/wp-content\/uploads\/2012\/07\/spezialkonstruktion_01_ed_ws-e1614956904701-300x222.png\" alt=\"Acoustic design of special building elements with respect to airborne sound insulation, impact sound insulation and structure-borne sound isolation\/ vibration isolation - connection between building facade to glass sword\" width=\"300\" height=\"222\" srcset=\"https:\/\/www.akustikforschung.de\/wp-content\/uploads\/2012\/07\/spezialkonstruktion_01_ed_ws-e1614956904701-300x222.png 300w, https:\/\/www.akustikforschung.de\/wp-content\/uploads\/2012\/07\/spezialkonstruktion_01_ed_ws-e1614956904701-640x473.png 640w, https:\/\/www.akustikforschung.de\/wp-content\/uploads\/2012\/07\/spezialkonstruktion_01_ed_ws-e1614956904701-768x567.png 768w, https:\/\/www.akustikforschung.de\/wp-content\/uploads\/2012\/07\/spezialkonstruktion_01_ed_ws-e1614956904701.png 800w\" sizes=\"auto, (max-width: 300px) 100vw, 300px\" \/><\/a><p id=\"caption-attachment-4597\" class=\"wp-caption-text\">Acoustic design of specific building elements<\/p><\/div>\n<div id=\"attachment_4811\" style=\"width: 310px\" class=\"wp-caption alignright\"><a href=\"https:\/\/www.akustikforschung.de\/wp-content\/uploads\/2013\/02\/berechnung_luftschalldaemmung_fassade_bastian_ed_ws.jpg\" rel=\"gallery\"><img loading=\"lazy\" decoding=\"async\" aria-describedby=\"caption-attachment-4811\" class=\"wp-image-4811 size-medium\" src=\"https:\/\/www.akustikforschung.de\/wp-content\/uploads\/2013\/02\/berechnung_luftschalldaemmung_fassade_bastian_ed_ws-e1614956928377-300x163.jpg\" alt=\"Simulation of airborne sound insulation of a building facade\" width=\"300\" height=\"163\" srcset=\"https:\/\/www.akustikforschung.de\/wp-content\/uploads\/2013\/02\/berechnung_luftschalldaemmung_fassade_bastian_ed_ws-e1614956928377-300x163.jpg 300w, https:\/\/www.akustikforschung.de\/wp-content\/uploads\/2013\/02\/berechnung_luftschalldaemmung_fassade_bastian_ed_ws-e1614956928377-640x348.jpg 640w, https:\/\/www.akustikforschung.de\/wp-content\/uploads\/2013\/02\/berechnung_luftschalldaemmung_fassade_bastian_ed_ws-e1614956928377-768x418.jpg 768w, https:\/\/www.akustikforschung.de\/wp-content\/uploads\/2013\/02\/berechnung_luftschalldaemmung_fassade_bastian_ed_ws-e1614956928377.jpg 800w\" sizes=\"auto, (max-width: 300px) 100vw, 300px\" \/><\/a><p id=\"caption-attachment-4811\" class=\"wp-caption-text\">Calculation of rated airborne sound reduction index of a building facade according to DIN\u00a0EN\u00a012354 by means of BASTIAN<sup>\u00ae<\/sup><\/p><\/div>\n<p><div id=\"attachment_11676\" style=\"width: 310px\" class=\"wp-caption alignright\"><a href=\"https:\/\/www.akustikforschung.de\/wp-content\/uploads\/2021\/11\/messung_schalldaemmung_02_ed3_ws_senderaum.jpg\" rel=\"gallery\"><img loading=\"lazy\" decoding=\"async\" aria-describedby=\"caption-attachment-11676\" class=\"wp-image-11676 size-medium\" src=\"https:\/\/www.akustikforschung.de\/wp-content\/uploads\/2021\/11\/messung_schalldaemmung_02_ed3_ws_senderaum-300x225.jpg\" alt=\"Measurement of sound-insulating properties of plate-shaped specimens\" width=\"300\" height=\"225\" srcset=\"https:\/\/www.akustikforschung.de\/wp-content\/uploads\/2021\/11\/messung_schalldaemmung_02_ed3_ws_senderaum-300x225.jpg 300w, https:\/\/www.akustikforschung.de\/wp-content\/uploads\/2021\/11\/messung_schalldaemmung_02_ed3_ws_senderaum-640x480.jpg 640w, https:\/\/www.akustikforschung.de\/wp-content\/uploads\/2021\/11\/messung_schalldaemmung_02_ed3_ws_senderaum-768x576.jpg 768w, https:\/\/www.akustikforschung.de\/wp-content\/uploads\/2021\/11\/messung_schalldaemmung_02_ed3_ws_senderaum.jpg 800w\" sizes=\"auto, (max-width: 300px) 100vw, 300px\" \/><\/a><p id=\"caption-attachment-11676\" class=\"wp-caption-text\">Measurement of sound insulation \/ transmission loss of materials and components in the test setup for windows with reduced dimensions in the sense of DIN EN ISO 10140-2<\/p><\/div><\/p>","protected":false},"excerpt":{"rendered":"<p>Concerning building acoustics, the Gesellschaft f\u00fcr Akustikforschung Dresden mbH provides advice for planning and optimization of both present and emerging [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":1910,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[19],"tags":[85,495,68,60,441,502,595,453,451,452,673,62,449,57,54,47,56,65,197,440,63,448,66,454,58,59,67],"class_list":["post-133","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-bauakustik","tag-auslegung","tag-bauakustik","tag-deckenprufstand","tag-din-4109","tag-din-en-12354","tag-din-en-16283","tag-din-en-iso-10140-2","tag-din-en-iso-10848","tag-din-en-iso-140","tag-din-en-iso-717","tag-din-en-iso-10140-3","tag-fensterprufstand","tag-korperschallisolation","tag-luftschalldammmass","tag-luftschalldammung","tag-messung","tag-normtrittschallpegel","tag-schalldammung","tag-schallquelle","tag-schallschutz","tag-schallschutz-gutachten","tag-trittschalldammung","tag-turprufstand","tag-vdi-2566","tag-vdi-3738","tag-vdi-4100","tag-wandprufstand","has-content-parts","content-parts-5"],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v26.9 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>Schallschutz - bauakustische Auslegung, Schallschutz-Gutachten<\/title>\n<meta name=\"description\" content=\"Bauakustische Auslegung, Schallschutz-Gutachten DIN 4109, VDI 4100, DIN EN 12354, Messung Schalld\u00e4mmung DIN EN ISO 10140, DIN EN ISO 140\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.akustikforschung.de\/en\/leistungen\/bau-und-raumakustik\/bauakustik\/bauakustische-auslegung-schallschutz\/\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Schallschutz - bauakustische Auslegung, Schallschutz-Gutachten\" \/>\n<meta property=\"og:description\" content=\"Bauakustische Auslegung, Schallschutz-Gutachten DIN 4109, VDI 4100, DIN EN 12354, Messung Schalld\u00e4mmung DIN EN ISO 10140, DIN EN ISO 140\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.akustikforschung.de\/en\/leistungen\/bau-und-raumakustik\/bauakustik\/bauakustische-auslegung-schallschutz\/\" \/>\n<meta property=\"og:site_name\" content=\"Gesellschaft f\u00fcr Akustikforschung Dresden mbH\" \/>\n<meta property=\"article:published_time\" content=\"2012-07-19T08:43:56+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2021-11-11T09:25:00+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/www.akustikforschung.de\/wp-content\/uploads\/2012\/07\/iStock_000005457175XSmall-e1614956859841.jpg\" \/>\n\t<meta property=\"og:image:width\" content=\"448\" \/>\n\t<meta property=\"og:image:height\" content=\"297\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/jpeg\" \/>\n<meta name=\"author\" content=\"admin\" \/>\n<meta name=\"twitter:label1\" content=\"Written by\" \/>\n\t<meta name=\"twitter:data1\" content=\"admin\" \/>\n\t<meta name=\"twitter:label2\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data2\" content=\"3 minutes\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\/\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\/\/www.akustikforschung.de\/en\/leistungen\/bau-und-raumakustik\/bauakustik\/bauakustische-auslegung-schallschutz\/#article\",\"isPartOf\":{\"@id\":\"https:\/\/www.akustikforschung.de\/en\/leistungen\/bau-und-raumakustik\/bauakustik\/bauakustische-auslegung-schallschutz\/\"},\"author\":{\"name\":\"admin\",\"@id\":\"https:\/\/www.akustikforschung.de\/#\/schema\/person\/abbae6675c827b688ca605c1363763b1\"},\"headline\":\"Design with respect to building acoustics &#8211; Noise protection\",\"datePublished\":\"2012-07-19T08:43:56+00:00\",\"dateModified\":\"2021-11-11T09:25:00+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\/\/www.akustikforschung.de\/en\/leistungen\/bau-und-raumakustik\/bauakustik\/bauakustische-auslegung-schallschutz\/\"},\"wordCount\":717,\"commentCount\":0,\"image\":{\"@id\":\"https:\/\/www.akustikforschung.de\/en\/leistungen\/bau-und-raumakustik\/bauakustik\/bauakustische-auslegung-schallschutz\/#primaryimage\"},\"thumbnailUrl\":\"https:\/\/www.akustikforschung.de\/wp-content\/uploads\/2012\/07\/iStock_000005457175XSmall-e1614956859841.jpg\",\"keywords\":[\"design\",\"Achitectural Acoustics\",\"test setup for ceilings\",\"DIN 4109\",\"DIN EN 12354\",\"DIN EN 16283\",\"DIN EN ISO 10140-2\",\"DIN EN ISO 10848\",\"DIN EN ISO 140\",\"DIN EN ISO 717\",\"DIN\u00a0EN\u00a0ISO\u00a010140-3\",\"test setup for windows\",\"structure-borne sound insulation\",\"airborne sound reduction index\",\"airborne sound insulation\",\"measurement\",\"impact sound pressure level\",\"sound insulation\",\"sound source\",\"noise control\",\"certificate for noise control\",\"impact sound insulation\",\"test setup for doors\",\"VDI 2566\",\"VDI 3738\",\"VDI 4100\",\"test setup for walls\"],\"articleSection\":[\"Achitectural Acoustics\"],\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"CommentAction\",\"name\":\"Comment\",\"target\":[\"https:\/\/www.akustikforschung.de\/en\/leistungen\/bau-und-raumakustik\/bauakustik\/bauakustische-auslegung-schallschutz\/#respond\"]}]},{\"@type\":\"WebPage\",\"@id\":\"https:\/\/www.akustikforschung.de\/en\/leistungen\/bau-und-raumakustik\/bauakustik\/bauakustische-auslegung-schallschutz\/\",\"url\":\"https:\/\/www.akustikforschung.de\/en\/leistungen\/bau-und-raumakustik\/bauakustik\/bauakustische-auslegung-schallschutz\/\",\"name\":\"Schallschutz - bauakustische Auslegung, Schallschutz-Gutachten\",\"isPartOf\":{\"@id\":\"https:\/\/www.akustikforschung.de\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\/\/www.akustikforschung.de\/en\/leistungen\/bau-und-raumakustik\/bauakustik\/bauakustische-auslegung-schallschutz\/#primaryimage\"},\"image\":{\"@id\":\"https:\/\/www.akustikforschung.de\/en\/leistungen\/bau-und-raumakustik\/bauakustik\/bauakustische-auslegung-schallschutz\/#primaryimage\"},\"thumbnailUrl\":\"https:\/\/www.akustikforschung.de\/wp-content\/uploads\/2012\/07\/iStock_000005457175XSmall-e1614956859841.jpg\",\"datePublished\":\"2012-07-19T08:43:56+00:00\",\"dateModified\":\"2021-11-11T09:25:00+00:00\",\"author\":{\"@id\":\"https:\/\/www.akustikforschung.de\/#\/schema\/person\/abbae6675c827b688ca605c1363763b1\"},\"description\":\"Bauakustische Auslegung, Schallschutz-Gutachten DIN 4109, VDI 4100, DIN EN 12354, Messung Schalld\u00e4mmung DIN EN ISO 10140, DIN EN ISO 140\",\"breadcrumb\":{\"@id\":\"https:\/\/www.akustikforschung.de\/en\/leistungen\/bau-und-raumakustik\/bauakustik\/bauakustische-auslegung-schallschutz\/#breadcrumb\"},\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\/\/www.akustikforschung.de\/en\/leistungen\/bau-und-raumakustik\/bauakustik\/bauakustische-auslegung-schallschutz\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\/\/www.akustikforschung.de\/en\/leistungen\/bau-und-raumakustik\/bauakustik\/bauakustische-auslegung-schallschutz\/#primaryimage\",\"url\":\"https:\/\/www.akustikforschung.de\/wp-content\/uploads\/2012\/07\/iStock_000005457175XSmall-e1614956859841.jpg\",\"contentUrl\":\"https:\/\/www.akustikforschung.de\/wp-content\/uploads\/2012\/07\/iStock_000005457175XSmall-e1614956859841.jpg\",\"width\":448,\"height\":297,\"caption\":\"Acoustic design of specific building elements\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\/\/www.akustikforschung.de\/en\/leistungen\/bau-und-raumakustik\/bauakustik\/bauakustische-auslegung-schallschutz\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\/\/www.akustikforschung.de\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Design with respect to building acoustics &#8211; Noise protection\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\/\/www.akustikforschung.de\/#website\",\"url\":\"https:\/\/www.akustikforschung.de\/\",\"name\":\"Gesellschaft f\u00fcr Akustikforschung Dresden mbH\",\"description\":\"Research &amp; Development - Test - Consultancy\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\/\/www.akustikforschung.de\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"en-US\"},{\"@type\":\"Person\",\"@id\":\"https:\/\/www.akustikforschung.de\/#\/schema\/person\/abbae6675c827b688ca605c1363763b1\",\"name\":\"admin\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\/\/www.akustikforschung.de\/#\/schema\/person\/image\/\",\"url\":\"https:\/\/secure.gravatar.com\/avatar\/1be4d41fdaa1450e74d8eee465d91370f7131fb4695757702869773133a254c3?s=96&d=mm&r=g\",\"contentUrl\":\"https:\/\/secure.gravatar.com\/avatar\/1be4d41fdaa1450e74d8eee465d91370f7131fb4695757702869773133a254c3?s=96&d=mm&r=g\",\"caption\":\"admin\"},\"url\":\"https:\/\/www.akustikforschung.de\/en\/author\/admin\/\"}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"Schallschutz - bauakustische Auslegung, Schallschutz-Gutachten","description":"Bauakustische Auslegung, Schallschutz-Gutachten DIN 4109, VDI 4100, DIN EN 12354, Messung Schalld\u00e4mmung DIN EN ISO 10140, DIN EN ISO 140","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.akustikforschung.de\/en\/leistungen\/bau-und-raumakustik\/bauakustik\/bauakustische-auslegung-schallschutz\/","og_locale":"en_US","og_type":"article","og_title":"Schallschutz - bauakustische Auslegung, Schallschutz-Gutachten","og_description":"Bauakustische Auslegung, Schallschutz-Gutachten DIN 4109, VDI 4100, DIN EN 12354, Messung Schalld\u00e4mmung DIN EN ISO 10140, DIN EN ISO 140","og_url":"https:\/\/www.akustikforschung.de\/en\/leistungen\/bau-und-raumakustik\/bauakustik\/bauakustische-auslegung-schallschutz\/","og_site_name":"Gesellschaft f\u00fcr Akustikforschung Dresden mbH","article_published_time":"2012-07-19T08:43:56+00:00","article_modified_time":"2021-11-11T09:25:00+00:00","og_image":[{"width":448,"height":297,"url":"https:\/\/www.akustikforschung.de\/wp-content\/uploads\/2012\/07\/iStock_000005457175XSmall-e1614956859841.jpg","type":"image\/jpeg"}],"author":"admin","twitter_misc":{"Written by":"admin","Est. reading time":"3 minutes"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/www.akustikforschung.de\/en\/leistungen\/bau-und-raumakustik\/bauakustik\/bauakustische-auslegung-schallschutz\/#article","isPartOf":{"@id":"https:\/\/www.akustikforschung.de\/en\/leistungen\/bau-und-raumakustik\/bauakustik\/bauakustische-auslegung-schallschutz\/"},"author":{"name":"admin","@id":"https:\/\/www.akustikforschung.de\/#\/schema\/person\/abbae6675c827b688ca605c1363763b1"},"headline":"Design with respect to building acoustics &#8211; Noise protection","datePublished":"2012-07-19T08:43:56+00:00","dateModified":"2021-11-11T09:25:00+00:00","mainEntityOfPage":{"@id":"https:\/\/www.akustikforschung.de\/en\/leistungen\/bau-und-raumakustik\/bauakustik\/bauakustische-auslegung-schallschutz\/"},"wordCount":717,"commentCount":0,"image":{"@id":"https:\/\/www.akustikforschung.de\/en\/leistungen\/bau-und-raumakustik\/bauakustik\/bauakustische-auslegung-schallschutz\/#primaryimage"},"thumbnailUrl":"https:\/\/www.akustikforschung.de\/wp-content\/uploads\/2012\/07\/iStock_000005457175XSmall-e1614956859841.jpg","keywords":["design","Achitectural Acoustics","test setup for ceilings","DIN 4109","DIN EN 12354","DIN EN 16283","DIN EN ISO 10140-2","DIN EN ISO 10848","DIN EN ISO 140","DIN EN ISO 717","DIN\u00a0EN\u00a0ISO\u00a010140-3","test setup for windows","structure-borne sound insulation","airborne sound reduction index","airborne sound insulation","measurement","impact sound pressure level","sound insulation","sound source","noise control","certificate for noise control","impact sound insulation","test setup for doors","VDI 2566","VDI 3738","VDI 4100","test setup for walls"],"articleSection":["Achitectural Acoustics"],"inLanguage":"en-US","potentialAction":[{"@type":"CommentAction","name":"Comment","target":["https:\/\/www.akustikforschung.de\/en\/leistungen\/bau-und-raumakustik\/bauakustik\/bauakustische-auslegung-schallschutz\/#respond"]}]},{"@type":"WebPage","@id":"https:\/\/www.akustikforschung.de\/en\/leistungen\/bau-und-raumakustik\/bauakustik\/bauakustische-auslegung-schallschutz\/","url":"https:\/\/www.akustikforschung.de\/en\/leistungen\/bau-und-raumakustik\/bauakustik\/bauakustische-auslegung-schallschutz\/","name":"Schallschutz - bauakustische Auslegung, Schallschutz-Gutachten","isPartOf":{"@id":"https:\/\/www.akustikforschung.de\/#website"},"primaryImageOfPage":{"@id":"https:\/\/www.akustikforschung.de\/en\/leistungen\/bau-und-raumakustik\/bauakustik\/bauakustische-auslegung-schallschutz\/#primaryimage"},"image":{"@id":"https:\/\/www.akustikforschung.de\/en\/leistungen\/bau-und-raumakustik\/bauakustik\/bauakustische-auslegung-schallschutz\/#primaryimage"},"thumbnailUrl":"https:\/\/www.akustikforschung.de\/wp-content\/uploads\/2012\/07\/iStock_000005457175XSmall-e1614956859841.jpg","datePublished":"2012-07-19T08:43:56+00:00","dateModified":"2021-11-11T09:25:00+00:00","author":{"@id":"https:\/\/www.akustikforschung.de\/#\/schema\/person\/abbae6675c827b688ca605c1363763b1"},"description":"Bauakustische Auslegung, Schallschutz-Gutachten DIN 4109, VDI 4100, DIN EN 12354, Messung Schalld\u00e4mmung DIN EN ISO 10140, DIN EN ISO 140","breadcrumb":{"@id":"https:\/\/www.akustikforschung.de\/en\/leistungen\/bau-und-raumakustik\/bauakustik\/bauakustische-auslegung-schallschutz\/#breadcrumb"},"inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.akustikforschung.de\/en\/leistungen\/bau-und-raumakustik\/bauakustik\/bauakustische-auslegung-schallschutz\/"]}]},{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/www.akustikforschung.de\/en\/leistungen\/bau-und-raumakustik\/bauakustik\/bauakustische-auslegung-schallschutz\/#primaryimage","url":"https:\/\/www.akustikforschung.de\/wp-content\/uploads\/2012\/07\/iStock_000005457175XSmall-e1614956859841.jpg","contentUrl":"https:\/\/www.akustikforschung.de\/wp-content\/uploads\/2012\/07\/iStock_000005457175XSmall-e1614956859841.jpg","width":448,"height":297,"caption":"Acoustic design of specific building elements"},{"@type":"BreadcrumbList","@id":"https:\/\/www.akustikforschung.de\/en\/leistungen\/bau-und-raumakustik\/bauakustik\/bauakustische-auslegung-schallschutz\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/www.akustikforschung.de\/"},{"@type":"ListItem","position":2,"name":"Design with respect to building acoustics &#8211; Noise protection"}]},{"@type":"WebSite","@id":"https:\/\/www.akustikforschung.de\/#website","url":"https:\/\/www.akustikforschung.de\/","name":"Gesellschaft f\u00fcr Akustikforschung Dresden mbH","description":"Research &amp; Development - Test - Consultancy","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/www.akustikforschung.de\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"en-US"},{"@type":"Person","@id":"https:\/\/www.akustikforschung.de\/#\/schema\/person\/abbae6675c827b688ca605c1363763b1","name":"admin","image":{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/www.akustikforschung.de\/#\/schema\/person\/image\/","url":"https:\/\/secure.gravatar.com\/avatar\/1be4d41fdaa1450e74d8eee465d91370f7131fb4695757702869773133a254c3?s=96&d=mm&r=g","contentUrl":"https:\/\/secure.gravatar.com\/avatar\/1be4d41fdaa1450e74d8eee465d91370f7131fb4695757702869773133a254c3?s=96&d=mm&r=g","caption":"admin"},"url":"https:\/\/www.akustikforschung.de\/en\/author\/admin\/"}]}},"_links":{"self":[{"href":"https:\/\/www.akustikforschung.de\/en\/wp-json\/wp\/v2\/posts\/133","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.akustikforschung.de\/en\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.akustikforschung.de\/en\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.akustikforschung.de\/en\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/www.akustikforschung.de\/en\/wp-json\/wp\/v2\/comments?post=133"}],"version-history":[{"count":8,"href":"https:\/\/www.akustikforschung.de\/en\/wp-json\/wp\/v2\/posts\/133\/revisions"}],"predecessor-version":[{"id":11683,"href":"https:\/\/www.akustikforschung.de\/en\/wp-json\/wp\/v2\/posts\/133\/revisions\/11683"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.akustikforschung.de\/en\/wp-json\/wp\/v2\/media\/1910"}],"wp:attachment":[{"href":"https:\/\/www.akustikforschung.de\/en\/wp-json\/wp\/v2\/media?parent=133"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.akustikforschung.de\/en\/wp-json\/wp\/v2\/categories?post=133"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.akustikforschung.de\/en\/wp-json\/wp\/v2\/tags?post=133"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}