{"id":6360,"date":"2014-03-22T20:10:21","date_gmt":"2014-03-22T20:10:21","guid":{"rendered":"https:\/\/www.akustik-forschung.de\/test\/?p=6360"},"modified":"2025-02-05T18:11:28","modified_gmt":"2025-02-05T17:11:28","slug":"schalldaempfer-pruefstand-acoustitube-hightemp","status":"publish","type":"post","link":"https:\/\/www.akustikforschung.de\/en\/produkte\/messgerate\/schalldaempfer-pruefstand-acoustitube-hightemp\/","title":{"rendered":"Test setup for mufflers AcoustiTube<sup>&reg;&nbsp;HighTemp<\/sup>"},"content":{"rendered":"<p><a href=\"https:\/\/www.akustikforschung.de\/wp-content\/uploads\/2025\/02\/schalldaempferpruefstand_acoustitube_hightemp_heizung_basismodul_04ed_ws-1.png\" rel=\"gallery\"><img loading=\"lazy\" decoding=\"async\" class=\"alignright wp-image-12194\" src=\"https:\/\/www.akustikforschung.de\/wp-content\/uploads\/2025\/02\/schalldaempferpruefstand_acoustitube_hightemp_heizung_basismodul_04ed_ws-1.png\" alt=\"Measurement of transmission loss and transfer function of exhaust silencers at near-service conditions in the test setup for mufflers AcoustiTube&lt;sup&gt;&amp;#174;&amp;nbsp;Hightemp&lt;\/sup&gt;\" width=\"600\" height=\"418\" \/><\/a><\/p>\n<p>The test setup for mufflers AcoustiTube<sup>\u00ae HighTemp<\/sup> allows the determination of the acoustic effectiveness of silencers and mufflers at temperatures up to 600 \u00b0C.<\/p>\n<p>Due to its small size compared to typical test setups for mufflers, the measuring device can be installed in a laboratory as well.<\/p>\n<p><!--contentpartdivider--><\/p>\n<h4>Fields of application of test setup for mufflers<\/h4>\n<p>Among other things, the operational area of the measuring system includes:<\/p>\n<ul>\n<li>test setup for mufflers (suitable for application in the laboratory as well)<\/li>\n<li>measurement of the spectral transmission loss of silencers and mufflers at high temperatures in a transmission tube<\/li>\n<li>application of measurement data as input parameters for calculating the spectral transmission loss and the spectral insertion loss of complete systems of silencers and mufflers by means of the analysis software <a href=\"https:\/\/www.akustikforschung.de\/en\/produkte\/software\/schalldampfer-software-aed-8001-acousticalc\/\">AcoustiCalc<sup>\u00ae Silencer<\/sup><\/a> (consideration of peripheral components, e. g. installation of a measured muffler within a complete exhaust system)<\/li>\n<li>application of measuring device as impedance tube<\/li>\n<\/ul>\n<h4>Software<\/h4>\n<p>The test setup for mufflers and silencers is supported by the analysis software AcoustiStudio &#8211; Module Sound Transmission.<\/p>\n<ul>\n<li>applicaton of the Two Source Method with 4 microphones for determining the transmission loss and the transfer matrix of silencers and mufflers as a function of frequency<\/li>\n<li>alternative applicaton of the Two Load Method with 4 microphones for determining the transmission loss and the transfer matrix of silencers and mufflers<\/li>\n<li>alternative measurement of transmission loss of silencers and mufflers according to DIN EN ISO 11820<\/li>\n<li>comfortable storage and management of measurement data in database system<\/li>\n<li>direct comparison of measurement results with simulation results of the muffler software <a href=\"https:\/\/www.akustikforschung.de\/en\/produkte\/software\/schalldampfer-software-aed-8001-acousticalc\/\">AcoustiCalc<sup>\u00ae Silencer<\/sup><\/a><\/li>\n<li>calculation of third octave band spectra, octave band spectra and average values<\/li>\n<\/ul>\n<blockquote>\n<h4>Technical Data<\/h4>\n<h5>Transmission tube system<\/h5>\n<ul>\n<li>consisting of each 2 measuring units, speakers and mufflers<\/li>\n<li>robust construction<\/li>\n<li>temperature durability of all components: up to 600 \u00b0C<\/li>\n<li>system diameter\n<ul>\n<li>type 1\n<ul>\n<li>inner diameter: 66 mm<\/li>\n<li>frequency range, fluid temperature 20 \u00b0C:<br \/>\nca. 30 Hz to 3.000 Hz<\/li>\n<li>frequency range, fluid temperature 600 \u00b0C:<br \/>\nca. 50 Hz to 5.200 Hz<\/li>\n<\/ul>\n<\/li>\n<\/ul>\n<ul>\n<li>type 2\n<ul>\n<li>inner diameter: 38 mm<\/li>\n<li>frequency range, fluid temperature 20 \u00b0C:<br \/>\nca. 30 Hz to 5.300 Hz<\/li>\n<li>frequency range, fluid temperature 600 \u00b0C:<br \/>\nca. 50 Hz to 9.100 Hz<\/li>\n<\/ul>\n<\/li>\n<\/ul>\n<\/li>\n<li>4 selectable positions for microphone probes per measuring unit<\/li>\n<\/ul>\n<h5>Heating system<\/h5>\n<ul>\n<li>consisting of heater and ventilator<\/li>\n<li>independent feedback control system<\/li>\n<li>max. temperature: 650 \u00b0C (at the output of the heater)<\/li>\n<li>max. volume flow: 6.000 l\/min (fluid temperature 20 \u00b0C, ventilator at 3.600 rpm)<\/li>\n<\/ul>\n<h5>Sensors<\/h5>\n<ul>\n<li>4 microphone probes<\/li>\n<li>2 temperature probes<\/li>\n<\/ul>\n<\/blockquote>\n<p><!--contentpartdivider--><\/p>\n<div id=\"attachment_12186\" style=\"width: 310px\" class=\"wp-caption alignright\"><a href=\"https:\/\/www.akustikforschung.de\/wp-content\/uploads\/2025\/02\/schalldaempferpruefstand_acoustitube_hightemp_heizung_basismodul_04b_ws.png\" rel=\"gallery\"><img loading=\"lazy\" decoding=\"async\" aria-describedby=\"caption-attachment-12186\" class=\"wp-image-12186\" src=\"https:\/\/www.akustikforschung.de\/wp-content\/uploads\/2025\/02\/schalldaempferpruefstand_acoustitube_hightemp_heizung_basismodul_04b_ws.png\" alt=\"Detailed view of test setup for mufflers AcoustiTube&lt;sup&gt;\u00ae HighTemp&lt;\/sup&gt; for measurement of spectral transmission loss of exhaust mufflers and silencers in the laboratory at temperatures up to 600 \u00b0C\" width=\"300\" height=\"216\" \/><\/a><p id=\"caption-attachment-12186\" class=\"wp-caption-text\">Heating system with ventilation, coupling silencer and test sound source<\/p><\/div>\n<p><a href=\"https:\/\/www.akustikforschung.de\/wp-content\/uploads\/2014\/05\/afd1401_05_ed2_ws.jpg\" rel=\"gallery\"><img loading=\"lazy\" decoding=\"async\" class=\"alignright wp-image-7117 size-medium\" src=\"https:\/\/www.akustikforschung.de\/wp-content\/uploads\/2014\/05\/afd1401_05_ed2_ws-300x300.jpg\" alt=\"Software for test setup of mufflers and silencers AcoustiTube&lt;sup&gt;\u00ae HighTemp&lt;\/sup&gt;\" width=\"300\" height=\"300\" srcset=\"https:\/\/www.akustikforschung.de\/wp-content\/uploads\/2014\/05\/afd1401_05_ed2_ws-300x300.jpg 300w, https:\/\/www.akustikforschung.de\/wp-content\/uploads\/2014\/05\/afd1401_05_ed2_ws-150x150.jpg 150w, https:\/\/www.akustikforschung.de\/wp-content\/uploads\/2014\/05\/afd1401_05_ed2_ws-297x297.jpg 297w, https:\/\/www.akustikforschung.de\/wp-content\/uploads\/2014\/05\/afd1401_05_ed2_ws-440x439.jpg 440w, https:\/\/www.akustikforschung.de\/wp-content\/uploads\/2014\/05\/afd1401_05_ed2_ws-75x75.jpg 75w, https:\/\/www.akustikforschung.de\/wp-content\/uploads\/2014\/05\/afd1401_05_ed2_ws.jpg 600w\" sizes=\"auto, (max-width: 300px) 100vw, 300px\" \/><\/a><\/p>\n<div id=\"attachment_12182\" style=\"width: 310px\" class=\"wp-caption alignright\"><a href=\"https:\/\/www.akustikforschung.de\/wp-content\/uploads\/2025\/02\/acoustistudio_modul_schalltransmission_schalldaempfer_03_durchgangsdaempfung_ws.jpg\" rel=\"gallery\"><img loading=\"lazy\" decoding=\"async\" aria-describedby=\"caption-attachment-12182\" class=\"wp-image-12182\" src=\"https:\/\/www.akustikforschung.de\/wp-content\/uploads\/2025\/02\/acoustistudio_modul_schalltransmission_schalldaempfer_03_durchgangsdaempfung_ws.jpg\" alt=\"Measurement of transmission loss and transfer function of exhaust silencers at near-service conditions in the test setup for mufflers AcoustiTube &lt;sup&gt;Hightemp&lt;\/sup&gt; \" width=\"300\" height=\"171\" \/><\/a><p id=\"caption-attachment-12182\" class=\"wp-caption-text\">Analysis software AcoustiStudio &#8211; Module Sound Transmission Silencers<\/p><\/div>\n<div id=\"attachment_6987\" style=\"width: 310px\" class=\"wp-caption alignright\"><a href=\"https:\/\/www.akustikforschung.de\/wp-content\/uploads\/2014\/03\/afd8001_08_ed_ws.jpg\" rel=\"gallery\"><img loading=\"lazy\" decoding=\"async\" aria-describedby=\"caption-attachment-6987\" class=\"wp-image-6987 size-medium\" src=\"https:\/\/www.akustikforschung.de\/wp-content\/uploads\/2014\/03\/afd8001_08_ed_ws-300x238.jpg\" alt=\"Calculation of transmission loss of exhaust systems with muffler software AcoustiCalc&lt;sup&gt;\u00ae Silencer&lt;\/sup&gt;\" width=\"300\" height=\"238\" srcset=\"https:\/\/www.akustikforschung.de\/wp-content\/uploads\/2014\/03\/afd8001_08_ed_ws-300x238.jpg 300w, https:\/\/www.akustikforschung.de\/wp-content\/uploads\/2014\/03\/afd8001_08_ed_ws-640x509.jpg 640w, https:\/\/www.akustikforschung.de\/wp-content\/uploads\/2014\/03\/afd8001_08_ed_ws-440x350.jpg 440w, https:\/\/www.akustikforschung.de\/wp-content\/uploads\/2014\/03\/afd8001_08_ed_ws.jpg 754w\" sizes=\"auto, (max-width: 300px) 100vw, 300px\" \/><\/a><p id=\"caption-attachment-6987\" class=\"wp-caption-text\">Calculation of acoustic efficiency of a muffler that was evaluated by the measuring system AcoustiTube<sup>\u00ae HighTemp<\/sup> within a complete exhaust system by means of the muffler software <a href=\"https:\/\/www.akustikforschung.de\/en\/produkte\/software\/schalldampfer-software-aed-8001-acousticalc\/\">AcoustiCalc<sup>\u00ae Silencer<\/sup><\/a><\/p><\/div>\n<p><div id=\"attachment_12124\" style=\"width: 310px\" class=\"wp-caption alignright\"><a href=\"https:\/\/www.akustikforschung.de\/wp-content\/uploads\/2025\/02\/Measuring_Instruments_vs_Analysis_Software_Overview_ws.png\" rel=\"gallery\"><img loading=\"lazy\" decoding=\"async\" aria-describedby=\"caption-attachment-12124\" class=\"wp-image-12124\" src=\"https:\/\/www.akustikforschung.de\/wp-content\/uploads\/2025\/02\/Measuring_Instruments_vs_Analysis_Software_Overview_ws.png\" alt=\"Interaction of measuring systems and analysis software for acoustic design of mufflers and silencers and multi-layer systems of absorbers\" width=\"300\" height=\"215\" \/><\/a><p id=\"caption-attachment-12124\" class=\"wp-caption-text\"><a href=\"https:\/\/www.akustikforschung.de\/wp-content\/uploads\/2025\/02\/Measuring_Instruments_vs_Analysis_Software_Overview.pdf\">Overview<\/a> of measuring systems vs. analysis software for acoustic design of mufflers and silencers and multi-layer systems of absorbers<\/p><\/div><\/p>","protected":false},"excerpt":{"rendered":"<p><\/br>The test setup for mufflers AcoustiTube<sup>\u00ae HighTemp<\/sup> allows the determination of the acoustic efficiency of silencers and mufflers at temperatures up to 600 \u00b0C. Due to its small size compared to typical test setups for mufflers, the measuring device can be installed in a laboratory as well.<\/p>\n<p>The gained measurement data of an evaluated muffler can be applied as input parameters for calculating the spectral transmission loss or the spectral insertion loss of complete systems of silencers and mufflers by means of the analysis software AcoustiCalc<sup>\u00ae&nbsp;Silencer<\/sup> as in the case that the measured muffler is integrated to a complete exhaust system.<\/p>\n","protected":false},"author":6,"featured_media":10114,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[32],"tags":[400,229,181,662,415,376,137,47,168,414,394,663,387],"class_list":["post-6360","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-messgerate","tag-abgassystem","tag-durchgangsdampfung","tag-einfugungsdampfung","tag-heiss","tag-labor","tag-messgerat","tag-messsystem","tag-messung","tag-schalldampfer","tag-schalldampfer-prufstand","tag-schalldampfung","tag-temperatur","tag-transmissionsrohr","has-content-parts","content-parts-5"],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v26.9 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>Schalld\u00e4mpfer-Pr\u00fcfstand, Messger\u00e4t, Messung Schalld\u00e4mpfung, hei\u00df<\/title>\n<meta name=\"description\" content=\"Schalld\u00e4mpfer-Pr\u00fcfstand, Messung von Schalld\u00e4mpfung bei hoher Temperatur, Messger\u00e4t, Bestimmung von Durchgangsd\u00e4mpfung, Einf\u00fcgungsd\u00e4mpfung.\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.akustikforschung.de\/produkte\/messgerate\/schalldaempfer-pruefstand-acoustitube-hightemp\/\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Schalld\u00e4mpfer-Pr\u00fcfstand, Messger\u00e4t, Messung Schalld\u00e4mpfung, hei\u00df\" \/>\n<meta property=\"og:description\" content=\"Schalld\u00e4mpfer-Pr\u00fcfstand, Messung von Schalld\u00e4mpfung bei hoher Temperatur, Messger\u00e4t, Bestimmung von Durchgangsd\u00e4mpfung, Einf\u00fcgungsd\u00e4mpfung.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.akustikforschung.de\/produkte\/messgerate\/schalldaempfer-pruefstand-acoustitube-hightemp\/\" \/>\n<meta property=\"og:site_name\" content=\"Gesellschaft f\u00fcr Akustikforschung Dresden mbH\" \/>\n<meta property=\"article:published_time\" content=\"2014-03-22T20:10:21+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2025-02-05T17:11:28+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/www.akustikforschung.de\/wp-content\/uploads\/2018\/04\/aed1400_07_04_ws.png\" \/>\n\t<meta property=\"og:image:width\" content=\"1024\" \/>\n\t<meta property=\"og:image:height\" content=\"817\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/png\" \/>\n<meta name=\"author\" content=\"Habelt\" \/>\n<meta name=\"twitter:label1\" content=\"Written by\" \/>\n\t<meta name=\"twitter:data1\" content=\"Habelt\" \/>\n\t<meta name=\"twitter:label2\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data2\" content=\"4 minutes\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\/\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\/\/www.akustikforschung.de\/produkte\/messgerate\/schalldaempfer-pruefstand-acoustitube-hightemp\/#article\",\"isPartOf\":{\"@id\":\"https:\/\/www.akustikforschung.de\/produkte\/messgerate\/schalldaempfer-pruefstand-acoustitube-hightemp\/\"},\"author\":{\"name\":\"Habelt\",\"@id\":\"https:\/\/www.akustikforschung.de\/#\/schema\/person\/6ebcedb9982eae0e4dd5976b75ddb632\"},\"headline\":\"Test setup for mufflers AcoustiTube&reg;&nbsp;HighTemp\",\"datePublished\":\"2014-03-22T20:10:21+00:00\",\"dateModified\":\"2025-02-05T17:11:28+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\/\/www.akustikforschung.de\/produkte\/messgerate\/schalldaempfer-pruefstand-acoustitube-hightemp\/\"},\"wordCount\":893,\"commentCount\":0,\"image\":{\"@id\":\"https:\/\/www.akustikforschung.de\/produkte\/messgerate\/schalldaempfer-pruefstand-acoustitube-hightemp\/#primaryimage\"},\"thumbnailUrl\":\"https:\/\/www.akustikforschung.de\/wp-content\/uploads\/2018\/04\/aed1400_07_04_ws.png\",\"keywords\":[\"exhaustion system\",\"transmission loss\",\"insertion loss\",\"hei\u00df\",\"laboratory\",\"measuring device\",\"measuring system\",\"measurement\",\"Muffler\",\"test setup for mufflers\",\"transmission loss\",\"Temperatur\",\"transmission tube\"],\"articleSection\":[\"Measuring Instruments\"],\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"CommentAction\",\"name\":\"Comment\",\"target\":[\"https:\/\/www.akustikforschung.de\/produkte\/messgerate\/schalldaempfer-pruefstand-acoustitube-hightemp\/#respond\"]}]},{\"@type\":\"WebPage\",\"@id\":\"https:\/\/www.akustikforschung.de\/produkte\/messgerate\/schalldaempfer-pruefstand-acoustitube-hightemp\/\",\"url\":\"https:\/\/www.akustikforschung.de\/produkte\/messgerate\/schalldaempfer-pruefstand-acoustitube-hightemp\/\",\"name\":\"Schalld\u00e4mpfer-Pr\u00fcfstand, Messger\u00e4t, Messung Schalld\u00e4mpfung, hei\u00df\",\"isPartOf\":{\"@id\":\"https:\/\/www.akustikforschung.de\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\/\/www.akustikforschung.de\/produkte\/messgerate\/schalldaempfer-pruefstand-acoustitube-hightemp\/#primaryimage\"},\"image\":{\"@id\":\"https:\/\/www.akustikforschung.de\/produkte\/messgerate\/schalldaempfer-pruefstand-acoustitube-hightemp\/#primaryimage\"},\"thumbnailUrl\":\"https:\/\/www.akustikforschung.de\/wp-content\/uploads\/2018\/04\/aed1400_07_04_ws.png\",\"datePublished\":\"2014-03-22T20:10:21+00:00\",\"dateModified\":\"2025-02-05T17:11:28+00:00\",\"author\":{\"@id\":\"https:\/\/www.akustikforschung.de\/#\/schema\/person\/6ebcedb9982eae0e4dd5976b75ddb632\"},\"description\":\"Schalld\u00e4mpfer-Pr\u00fcfstand, Messung von Schalld\u00e4mpfung bei hoher Temperatur, Messger\u00e4t, Bestimmung von Durchgangsd\u00e4mpfung, Einf\u00fcgungsd\u00e4mpfung.\",\"breadcrumb\":{\"@id\":\"https:\/\/www.akustikforschung.de\/produkte\/messgerate\/schalldaempfer-pruefstand-acoustitube-hightemp\/#breadcrumb\"},\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\/\/www.akustikforschung.de\/produkte\/messgerate\/schalldaempfer-pruefstand-acoustitube-hightemp\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\/\/www.akustikforschung.de\/produkte\/messgerate\/schalldaempfer-pruefstand-acoustitube-hightemp\/#primaryimage\",\"url\":\"https:\/\/www.akustikforschung.de\/wp-content\/uploads\/2018\/04\/aed1400_07_04_ws.png\",\"contentUrl\":\"https:\/\/www.akustikforschung.de\/wp-content\/uploads\/2018\/04\/aed1400_07_04_ws.png\",\"width\":1024,\"height\":817,\"caption\":\"bbb\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\/\/www.akustikforschung.de\/produkte\/messgerate\/schalldaempfer-pruefstand-acoustitube-hightemp\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\/\/www.akustikforschung.de\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Schalld\u00e4mpfer-Pr\u00fcfstand AcoustiTube&reg;&nbsp;HighTemp\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\/\/www.akustikforschung.de\/#website\",\"url\":\"https:\/\/www.akustikforschung.de\/\",\"name\":\"Gesellschaft f\u00fcr Akustikforschung Dresden mbH\",\"description\":\"Research &amp; Development - Test - Consultancy\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\/\/www.akustikforschung.de\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"en-US\"},{\"@type\":\"Person\",\"@id\":\"https:\/\/www.akustikforschung.de\/#\/schema\/person\/6ebcedb9982eae0e4dd5976b75ddb632\",\"name\":\"Habelt\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\/\/www.akustikforschung.de\/#\/schema\/person\/image\/\",\"url\":\"https:\/\/secure.gravatar.com\/avatar\/5aae039a521eb1a6abae96312bf56fd12b5ce7c8179f0d2531104afe975e273f?s=96&d=mm&r=g\",\"contentUrl\":\"https:\/\/secure.gravatar.com\/avatar\/5aae039a521eb1a6abae96312bf56fd12b5ce7c8179f0d2531104afe975e273f?s=96&d=mm&r=g\",\"caption\":\"Habelt\"},\"url\":\"https:\/\/www.akustikforschung.de\/en\/author\/habelt\/\"}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"Schalld\u00e4mpfer-Pr\u00fcfstand, Messger\u00e4t, Messung Schalld\u00e4mpfung, hei\u00df","description":"Schalld\u00e4mpfer-Pr\u00fcfstand, Messung von Schalld\u00e4mpfung bei hoher Temperatur, Messger\u00e4t, Bestimmung von Durchgangsd\u00e4mpfung, Einf\u00fcgungsd\u00e4mpfung.","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.akustikforschung.de\/produkte\/messgerate\/schalldaempfer-pruefstand-acoustitube-hightemp\/","og_locale":"en_US","og_type":"article","og_title":"Schalld\u00e4mpfer-Pr\u00fcfstand, Messger\u00e4t, Messung Schalld\u00e4mpfung, hei\u00df","og_description":"Schalld\u00e4mpfer-Pr\u00fcfstand, Messung von Schalld\u00e4mpfung bei hoher Temperatur, Messger\u00e4t, Bestimmung von Durchgangsd\u00e4mpfung, Einf\u00fcgungsd\u00e4mpfung.","og_url":"https:\/\/www.akustikforschung.de\/produkte\/messgerate\/schalldaempfer-pruefstand-acoustitube-hightemp\/","og_site_name":"Gesellschaft f\u00fcr Akustikforschung Dresden mbH","article_published_time":"2014-03-22T20:10:21+00:00","article_modified_time":"2025-02-05T17:11:28+00:00","og_image":[{"width":1024,"height":817,"url":"https:\/\/www.akustikforschung.de\/wp-content\/uploads\/2018\/04\/aed1400_07_04_ws.png","type":"image\/png"}],"author":"Habelt","twitter_misc":{"Written by":"Habelt","Est. reading time":"4 minutes"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/www.akustikforschung.de\/produkte\/messgerate\/schalldaempfer-pruefstand-acoustitube-hightemp\/#article","isPartOf":{"@id":"https:\/\/www.akustikforschung.de\/produkte\/messgerate\/schalldaempfer-pruefstand-acoustitube-hightemp\/"},"author":{"name":"Habelt","@id":"https:\/\/www.akustikforschung.de\/#\/schema\/person\/6ebcedb9982eae0e4dd5976b75ddb632"},"headline":"Test setup for mufflers AcoustiTube&reg;&nbsp;HighTemp","datePublished":"2014-03-22T20:10:21+00:00","dateModified":"2025-02-05T17:11:28+00:00","mainEntityOfPage":{"@id":"https:\/\/www.akustikforschung.de\/produkte\/messgerate\/schalldaempfer-pruefstand-acoustitube-hightemp\/"},"wordCount":893,"commentCount":0,"image":{"@id":"https:\/\/www.akustikforschung.de\/produkte\/messgerate\/schalldaempfer-pruefstand-acoustitube-hightemp\/#primaryimage"},"thumbnailUrl":"https:\/\/www.akustikforschung.de\/wp-content\/uploads\/2018\/04\/aed1400_07_04_ws.png","keywords":["exhaustion system","transmission loss","insertion loss","hei\u00df","laboratory","measuring device","measuring system","measurement","Muffler","test setup for mufflers","transmission loss","Temperatur","transmission tube"],"articleSection":["Measuring Instruments"],"inLanguage":"en-US","potentialAction":[{"@type":"CommentAction","name":"Comment","target":["https:\/\/www.akustikforschung.de\/produkte\/messgerate\/schalldaempfer-pruefstand-acoustitube-hightemp\/#respond"]}]},{"@type":"WebPage","@id":"https:\/\/www.akustikforschung.de\/produkte\/messgerate\/schalldaempfer-pruefstand-acoustitube-hightemp\/","url":"https:\/\/www.akustikforschung.de\/produkte\/messgerate\/schalldaempfer-pruefstand-acoustitube-hightemp\/","name":"Schalld\u00e4mpfer-Pr\u00fcfstand, Messger\u00e4t, Messung Schalld\u00e4mpfung, hei\u00df","isPartOf":{"@id":"https:\/\/www.akustikforschung.de\/#website"},"primaryImageOfPage":{"@id":"https:\/\/www.akustikforschung.de\/produkte\/messgerate\/schalldaempfer-pruefstand-acoustitube-hightemp\/#primaryimage"},"image":{"@id":"https:\/\/www.akustikforschung.de\/produkte\/messgerate\/schalldaempfer-pruefstand-acoustitube-hightemp\/#primaryimage"},"thumbnailUrl":"https:\/\/www.akustikforschung.de\/wp-content\/uploads\/2018\/04\/aed1400_07_04_ws.png","datePublished":"2014-03-22T20:10:21+00:00","dateModified":"2025-02-05T17:11:28+00:00","author":{"@id":"https:\/\/www.akustikforschung.de\/#\/schema\/person\/6ebcedb9982eae0e4dd5976b75ddb632"},"description":"Schalld\u00e4mpfer-Pr\u00fcfstand, Messung von Schalld\u00e4mpfung bei hoher Temperatur, Messger\u00e4t, Bestimmung von Durchgangsd\u00e4mpfung, Einf\u00fcgungsd\u00e4mpfung.","breadcrumb":{"@id":"https:\/\/www.akustikforschung.de\/produkte\/messgerate\/schalldaempfer-pruefstand-acoustitube-hightemp\/#breadcrumb"},"inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.akustikforschung.de\/produkte\/messgerate\/schalldaempfer-pruefstand-acoustitube-hightemp\/"]}]},{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/www.akustikforschung.de\/produkte\/messgerate\/schalldaempfer-pruefstand-acoustitube-hightemp\/#primaryimage","url":"https:\/\/www.akustikforschung.de\/wp-content\/uploads\/2018\/04\/aed1400_07_04_ws.png","contentUrl":"https:\/\/www.akustikforschung.de\/wp-content\/uploads\/2018\/04\/aed1400_07_04_ws.png","width":1024,"height":817,"caption":"bbb"},{"@type":"BreadcrumbList","@id":"https:\/\/www.akustikforschung.de\/produkte\/messgerate\/schalldaempfer-pruefstand-acoustitube-hightemp\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/www.akustikforschung.de\/"},{"@type":"ListItem","position":2,"name":"Schalld\u00e4mpfer-Pr\u00fcfstand AcoustiTube&reg;&nbsp;HighTemp"}]},{"@type":"WebSite","@id":"https:\/\/www.akustikforschung.de\/#website","url":"https:\/\/www.akustikforschung.de\/","name":"Gesellschaft f\u00fcr Akustikforschung Dresden mbH","description":"Research &amp; Development - Test - Consultancy","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/www.akustikforschung.de\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"en-US"},{"@type":"Person","@id":"https:\/\/www.akustikforschung.de\/#\/schema\/person\/6ebcedb9982eae0e4dd5976b75ddb632","name":"Habelt","image":{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/www.akustikforschung.de\/#\/schema\/person\/image\/","url":"https:\/\/secure.gravatar.com\/avatar\/5aae039a521eb1a6abae96312bf56fd12b5ce7c8179f0d2531104afe975e273f?s=96&d=mm&r=g","contentUrl":"https:\/\/secure.gravatar.com\/avatar\/5aae039a521eb1a6abae96312bf56fd12b5ce7c8179f0d2531104afe975e273f?s=96&d=mm&r=g","caption":"Habelt"},"url":"https:\/\/www.akustikforschung.de\/en\/author\/habelt\/"}]}},"_links":{"self":[{"href":"https:\/\/www.akustikforschung.de\/en\/wp-json\/wp\/v2\/posts\/6360","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.akustikforschung.de\/en\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.akustikforschung.de\/en\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.akustikforschung.de\/en\/wp-json\/wp\/v2\/users\/6"}],"replies":[{"embeddable":true,"href":"https:\/\/www.akustikforschung.de\/en\/wp-json\/wp\/v2\/comments?post=6360"}],"version-history":[{"count":46,"href":"https:\/\/www.akustikforschung.de\/en\/wp-json\/wp\/v2\/posts\/6360\/revisions"}],"predecessor-version":[{"id":12197,"href":"https:\/\/www.akustikforschung.de\/en\/wp-json\/wp\/v2\/posts\/6360\/revisions\/12197"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.akustikforschung.de\/en\/wp-json\/wp\/v2\/media\/10114"}],"wp:attachment":[{"href":"https:\/\/www.akustikforschung.de\/en\/wp-json\/wp\/v2\/media?parent=6360"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.akustikforschung.de\/en\/wp-json\/wp\/v2\/categories?post=6360"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.akustikforschung.de\/en\/wp-json\/wp\/v2\/tags?post=6360"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}